Home Product Catalogue Neon & IP Loggers News & Brochures Product Support Where to Buy Connect To Our FTP Contact Us By Phone Contact Us By Email Staff Portal

Product Support

Product Alert #16

STARLOGGER DATA LOGGER - Model 6004A/B - Serial #s 301 to 750

Starlogger Issues

11 May 1994

16.1 V21.10/V22.1 Firmware Error – 1st count lost after loading scheme (Model 6004A)

Problem

After a scheme is loaded into a Model 6004A with V21.9 firmware, the first count into each counter channel will not be registered.

Note: This problem had been previoulsy corrected and was re- introduced in V21.9.

Correction

Upgrade the Model 6004A STARLOGGER to V21.11 Firmware.

16.2 Improved HSIO Compatibility in 6003 Mode (Model 6004A/B)

Problem

The STARLOGGER will recognise HSIO Clock selection from B10 of the Register Block. This enables Clock 1 to be used used with Data 0 (and Clock 0 with Data 1) in SERIN & SEROUT instructions.

There is no change to 6004 mode operation.

Correction

Upgrade the STARLOGGER to V21.11 Firmware (Model 6004A) or V22.2 Firmware (Model 6004B).