Home Products & Systems Neon & IP Loggers Newsline & Brochures Product Support Customer Survey 2008 Where to Buy Factory Location Contact Us

Products

Model: 7420 Technical Specs | Order Info

These high precision DRUCK transducers use a high integrity silicon diaphragm and are temperature compensated. They connect directly to a Model 7000 MACRO Data Logger (or via a 6142A Universal Amplifier Module to a Model 6004 STARLOGGER).

Each transducer comes factory-calibrated with a calibration certificate. A transducer for a wider calibrated temperature range of -20 to 80°C with an accuracy of ±1.5% of full scale is available on request.

Accuracy: ±0.5% (0 to 50°C)
Linearity/Hysteresis: ±0.1% of full scale
Operating temperature: -20 to 80°C
Calibrated temperature: 0 to 50°C
Overpressure: 3 times rated pressure
Pressure connection: ¼” NPT – flat end
Pressure media: gases and fluids compatible with silicon and titanium
Signal: 1 analog, 100mV @ 10V excitation
Cable: 4 core, 1 metre
Power: 5V or 10V, 5mA from Logger
Size: 21mm diameter, 75mm long
Weight: 170g

Model Description Range
7420B Pressure Transducer,
Gauge Type
0 to 50kPa
7420C 0 to 100kPa
7420D 0 to 200kPa
7420E 0 to 500kPa
7420F 0 to 1000kPa
7420G 0 to 2000kPa
6239 Pressure Transducers User Manual Supplement